AISAC control settings are made in the AISAC view.
To change an AISAC control that has already been applied, select it from the pull-down menu that displays the AISAC control.
AISAC has two control types: Normally, the programmer manually controls the AISAC control value.
By setting the control type, the designer can specify whether the value should be automatic or random.
The AISAC control types are as follows:
Item | Description | Control Value |
---|---|---|
Off | Control value is manually specified. | Can be controlled by AISAC control name. |
AISAC Auto Modulation | This type automatically changes the control value at the set time. | Design only. It changes automatically. |
Random AISAC | This type of control value changes within the set random range. The value is determined at the time of the playback request. | In the case of narrow random range, you can control the random center value. |
The default control value is the initial value of the AISAC control value during playback. It is applied when the AISAC control value is not specified during playback.
If you want to preview the default AISAC control values after moving the AISAC controls on the tool at least once, please "Reset the Previewer" before running the preview.
If multiple AISACs using the same AISAC control are assigned to the same object, the default AISAC control values follow the settings of the first AISAC item.
For example, if a track has Aisac_0(Any) and Aisac_1(Any) as shown above, the default AISAC control value of Aisac_0 will be effective.