Timeline Viewer

The Timeline Viewer displays the playback status of Cues and Voices, with the horizontal axis representing time and the vertical axis representing various Cues or Players by their names or handles.
In addition, you can check for any errors and Voice limiting control that may have occurred in chronological order.

About the bars displayed

  • An orange bar represents the period from when a Cue was triggered until when it was stopped.
  • A light blue bar represents the period from when a voice was played until when it was stopped.
  • The last one played will be displayed in front of each bar.
  • Virtualized voices appear shaded.
  • When you click on a bar, details about the corresponding item are displayed in the details log viewer.
    For more information, see Details log viewer .

Display of the AISAC control

The AISAC control value is displayed above the bar, only when the Track is displayed with the player handle.
It is displayed only when a new AISAC control value is set or updated.

About the flags displayed

A log indicating that an error or a voice limiting operation occurred is indicated by a flag mark at the top of the timeline viewer.
Just like fore Cues and Voice bars, you can check the item's details in the details log viewer by clicking on it.
The flags displayed are as follows:

List of flags

Display Log Description
"E" for the red flag Error Indicates that an error occurred.
"L" for the gray flag Sequence Limit Indicates that sequence limiting has occurred for the sequence called by the Cue.
This error occurs when the maximum number of sequences set in the Cue or Category is exceeded.
"V" for the gray flag Voice Limit Indicates that voice limiting has occurred.
This error occurs when the maximum number of voices set in the Voice Limit Group or Voice Pool has been exceeded.
"U" for the yellow green flag User Log Indicates that a user-specified log has been received.

About the list display

There is a list display button at the upper-left of the timeline viewer.

When this button is pressed, a list of the Cues and other items active at the specified time is displayed.

About display settings

When you press the settings button in the upper-left corner of the timeline viewer, a window appears allowing you to adjust its display settings.

The parameters that can be set are listed below.

Timeline Settings

Item Description
Track Type Specify whether to place the bars for a Track, a Cue or a Player handle.
Move updated Tracks to top automatically If this option is disabled, the tracks are arranged in the order in which the logs came.
If enabled, the tracks will be sorted automatically so that the last logs are displayed at the top.
AISAC Control Name When the value of the AISAC control is set to the Player, specify whether or not to display it and in what color. This setting is used only when the type of track is Player.

When you switch the type of track, the display changes as follows:

When a Cue is specified...

(When a Player is specified, the purple line displayed on the third track from the top becomes the display of the AISAC control value.)

Timeline list display setting

Item Description
Cue list order Specify the display order of the Cue in the timeline list.
CueSheet list order Specify the display order of the CueSheet in the timeline list.

About the voice volume log

When "Acquire Voice Volume" is enabled in the profiler recording settings, if you select a light blue voice bar, the volume will be displayed.
(The profiler recording settings are accessible from "Setting ..." on the capture menu.)

"Voice details" are opened and closed by double-clicking on the header.

Changing the scale of the display

To increase or reduce the size of the display, use the buttons or mouse wheel.